Datapath x4 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Aufnahmegeräte Datapath x4 herunter. Datapath x4 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

User ManualVersion 01.03.00 Display Controller

Seite 2 - Contents

DescriptionFront panelFig.1Operation IndicatorsThe front panel has three LEDs to indicate the operational status of the x4:• Power• Input• StatusPo

Seite 3 - Safety Instructions

Rear PanelFig.2Sync Sockets (Not x4-1U)The Sync sockets are provided for future genlock enhancements. They should be left unconnected.USB SocketThe U

Seite 4 - Introduction

DVI-D Input SocketThe DVI-D Input socket is used to connect the DVI input source to the x4. The x4 supports Dual Link DVI, Single Link DVI and also H

Seite 5 - Conguration Examples

Setting up the x4• Ensure the power supply for the DVI source is disconnected.• Connect the cable from the DVI source to the input socket on the rea

Seite 6

Conguring the x4Factory Default SettingsThe x4 stores a number of parameters to congure its operation. This allows it to operate stand alone in a v

Seite 7

Whenever the monitor EDID is used, the x4 will calculate the internal scale factors to ensure that the monitor (at whatever resolution it is being dri

Seite 8

Operating InstructionsDVI Input When the X4 is powered up successfully and the Power, Input and Status LED indicators are illuminated; this indicates

Seite 9 - Unpacking

x4 Control ApplicationApplication InstallationNote:Donotplugthex4intoaUSBportuntilthedriverinstallationiscomplete.Locate the Install

Seite 10 - Description

The main control dialog is divided into the following groups:Connection DiagramDVI-D InputInput Capture RegionsDeviceMonitor OutputsConnection Diagram

Seite 11 - Output Framelock (x4-1U only)

DVI-D InputThe DVI-D Input group displays the current DVI mode that is being captured (if any) and the preferred mode that has been programmed into th

Seite 12 - DVI-I Output Sockets

ContentsSafety Instructions 3Introduction

Seite 13 - Setting up the x4

The DVI-D Input dialog displays the resolution of the current mode for reference and allows the timings of the EDID preferred mode to be edited. To p

Seite 14 - Conguring the x4

All modications to the Input settings can be saved as part of a .vqs le, removing the requirement to input the same settings again. To save the set

Seite 15

Input Capture RegionsEach output of the x4 can select a dierent region of the input source image. This dialog (Fig. 11) displays the settings of ea

Seite 16 - Operating Instructions

Predened RegionsFor ease of use, there are preset buttons to select the two most popular congurations: Quarter or Replicate.QuarterThe rst monitor

Seite 17 - Application Installation

Individual monitor outputs can be congured by clicking on the corresponding Modify button. This will bring up a timing dialog similar to that of the

Seite 18 - Connection Diagram

The source of mode selection controls whether the x4 output should take its timing values and resolution from the preferred mode of the monitor that

Seite 19 - DVI-D Input

SpecicationPhysical Dimensions x4 - 235 x 175 x 44mm/9.25” x 6.9” x 1.75”x4-1U: 438 x 173 x 40mm/17.24” x 6.81” x 1.57”Operating Temperature Range

Seite 20

Datapath LimitedDatapath has a long and very successful history in the computer graphics industry. Datapath has been designing and supplying high per

Seite 21 - Limitations

28IndexAApplication Installation 17arbitrary crop 4Bbezel compensation 6Ccables up to 20m 19conguration 14Conguring the x4 16Connecting the x4

Seite 22 - Input Capture Regions

29Power Supply 3PSU Blades 9QQuarter 23RRear Panel 11regions to be displayed 15Replicate 23rotate to portrait 7Ssafety precautions 3Scaling Op

Seite 23 - Monitor Outputs

Safety InstructionsTo prevent damage to your Datapath product or injury to personnel operating the equipment, please read the following safety precaut

Seite 24

30UK Headquarters and Main Sales OceDatapath Ltd., Alfreton Road, Derby, DE21 4AD, UKTel: +44 (0) 1332 294441 Fax: +44 (0) 1332 290667Email: sales@d

Seite 25

IntroductionThe Datapath x4 is a stand alone display wall controller that accepts a standard single or dual-link DVI input and can exibly display thi

Seite 26 - Specication

Conguration ExamplesListed on the next few pages are just a few examples of what can be achieved with the Datapath x4. The list of examples is not d

Seite 27 - Datapath Limited

Divide the input signal into quadrants and display each quarter on separate displays with optional frame rate conversion (in this case 30Hz to 60Hz).

Seite 28

Duplicate the input signal x2 and display 1 on a single landscape display and divide the 2nd into thirds, rotate to portrait, upscale and split betwee

Seite 29

Crop the input signal into x4 and display x2 quarters landscape and x2 quarters portrait. Crop the input signal x4 rotate through 90º,180º or 270º, di

Seite 30

UnpackingYour packing box should contain the following items:• The x4 or x4-1U Display Wall Controller• The x4-PSU Power supply unit with internatio

Kommentare zu diesen Handbüchern